If the application errors occur while connected to the OnGuard application server using Remote Desktop Connection, where the OnGuard application server is running Windows Server 2008 R2, the password for the Login Driver might be out of sync with the database.Perform the steps in the Microsoft Knowledge Base article below to do this: Because Lenel does not currently support the use of the IPv6 protocol, it should be disabled.For more information, refer to KB article 3142, How to configure ODBC DSNs in 64-bit versions of Microsoft Windows. Only one 32-bit ODBC connection should be configured. If so, ensure the computer does not have a 32-bit ODBC connection and a 64-bit ODBC connection with the same name. Verify if the computer is running a 64-bit version of Windows.Follow the steps in the link below to repair. NET Framework 3.5.1 was already enabled, it might need to be repaired. Follow the steps in the link below to enable. NET Framework 3.5.1 Windows component must be enabled. Follow the instructions in KB article 2291, How to turn User Account Control (UAC) on or off in Windows Vista, Windows 7 or Windows Server 2008. User Account Control (UAC) must be disabled. All steps might not be required to resolve the issue. If the issue persists, proceed to the next step in order. After each step, attempt to open the affected OnGuard application again. To resolve this issue, follow the steps below. Similar failures might occur when opening the Universal Time Conversion utility or the System Management Console. If you click, one of the following blocks of information is shown, depending on which application failed to open:Īpplication Name: SystemAdministration.exe Windows is checking for a solution to the problem." "System Administration has stopped working When opening System Administration or Alarm Monitoring on a computer running Windows 7 or Windows Server 2008 R2, the application fails to open, and the following error message appears:
0 Comments
Leave a Reply. |